  keysight n8834a multiscope application achieve greater insight and productivity C infiniium 9000, s-series, 90000a, 90000 x-, 90000 q-, v-series and z-series infiniivision 2000 x-, 3000t x-, 3000a x-, 4000 x-, 6000 x-, 6000 and 7000b series data sheet
introduction introducing the new multiscope application need more than four simultaneous oscilloscope channels? ever placed two oscilloscopes together to see eight channels simultaneously? the keysight technologies, inc. n8834a multiscope application enables infiniium and infiniivision real-time oscilloscope users to bring multiple oscilloscopes together for measurement on a single timebase. capture, view, and analyze up to 40 time-correlated oscilloscope channels. if your need for more than four simultaneous channels goes away, each oscilloscope can be used independently and then brought back together when there are future needs for more than four channel measurements. are you working on applications like power rails, high-speed multi-lane serial buses, optical networking, or ddr memory systems? the n8834a multiscope software allows connection of 2 to 10 oscilloscopes to achieve up to 40 channels on a single timebase. each oscilloscope is daisy chained via cables and power splitters to the first oscilloscope, called the leader. automated calibration is available to allow channel correlation across frames down to less than 1 ps. all oscilloscopes connect to a control pc via lan or usb. the pc runs the infiniium application (user interface) and allows users to change settings on all oscilloscopes. the infiniium application on the pc shows all waveforms and measurements and offers analysis in addition to controlling the oscilloscope settings. the leader can also work as the controller in the absence of a control pc.
03 | keysight | n8834a multiscope application - data sheet multiscope connection of two s-series oscilloscopes. heterogeneous combination: one s-series oscilloscope and one 90000 x-series oscilloscope. features C save costs by connecting up to 10 of your existing infiniium series oscilloscopes to achieve 40 channel acquisitions in a single timebase. C data is presented to the user on a control pc or the leader scope as if all oscilloscope channels existed on a single frame. C oscilloscopes can be separated and used independently when four channels or fewer are needed. C application supports multiple frames using the same family of oscilloscopes (e.g. all v-series scopes) or a heterogeneous combination of different oscilloscope families (e.g. one 9000 series and one s-series). time-correlation precision depends on which frames are connected together. analyze data on pc. user can either connect to live data for online analysis via hosted mode or save the setup file to be viewed offline via offline mode. increase your productivity and effciency the n8834a multiscope software works well with the new pc- hosted mode, which allows you to see live signals acquired from the oscilloscopes on a pc installed with the n8900a infiniium offline oscilloscope analysis software. users can test lanes on the multiscope from the comfort of their own workbench. users can remotely login to the multiscope application from the pc and observe live traffic. the infiniium offline oscilloscope analysis software application allows users to save the setup and waveform files in a composite format (.osc) to be analyzed offline on the pc, freeing up the multiscope connection for others.
04 | keysight | n8834a multiscope application - data sheet multiscope software architecture control pc the n8834a multiscope application runs on a windows 7 pc. all the scopes are connected to the control pc via lan or usb. a control pc must be used if infiniivision scopes exist in the multiscope configuration. C pc supports both hosted/online and offline analysis. C scope front panels are disabled during multiscope operation. multiscope is controlled by a pc installed with the n8900a infiniium offline analysis software or the leader scope in the absence of a pc. C display up to 16 grids per window, up to 8 windows. C full support of all measurements, functions, and analysis on all channels. C test at the comfort of your workbench. leader scope is used to control and display multichannel waveforms. view of 6 channels and 3 eye diagrams on a single window with 8 grids. daisy chained connection with power splitter and bnc cables. the leader and the followers the leader oscilloscope connects to the control pc via lan or usb or can act as the controller in the absence of the pc. the one leader oscilloscope can connect two to nine followers. the connection between oscilloscopes is daisy chained with cables and splitters. C support edge or glitch trigger on leader (other triggering modes (including infiniiscan) are not supported). C one-time deskew eliminates frame-to-frame skew created by trigger daisy chain connection. C achieve inter-scope intrinsic jitter of 150 fs with precision calibration on the 90000 q-series and z-series infiniium oscilloscopes. C 10-mhz reference clock aligns sample for deep memory synchronization.
05 | keysight | n8834a multiscope application - data sheet calibration methods there are three calibration methods available with the n8834a multiscope software. each calibration method provides a different level of channel-to-channel skew value. manual calibration is available for users who are interested in viewing multi-channel signals but not concerned about the skew factor across channels. external trigger helps users achieve 100 ps channel-to-channel skew. the most accurate measurements can be achieved with the drift correction method with skew in the range of 200 fs. 1. manual manual calibration requires no cabling and users can achieve skew correction by manually dialing in the right skew values between the channels. infiniivision scopes supports only manual calibration. 2. basic the trigger out process provides the most basic level of inter- oscilloscope time synchronization. this process connects the trigger output signal (trig out) from the leader oscilloscope through each follower oscilloscope (aux trig) in a daisy chain configuration. the followers are each armed in descending order from furthest from the leader (f{n}) to nearest to the leader (f{1}). the leaders trigger is armed last. once the leader triggers, each follower will trigger in turn, down through the chain. 3. precision the horizontal position of channels within different oscilloscope frames can drift with temperature (inter-oscilloscope drift). the drift correction synchronization process corrects for this drift by monitoring the inter-oscilloscope drift on a separate, dedicated synchronization channel. the idea is that any time corrections that keep the synchronization channels aligned will also keep the signals aligned. precision calibration will consume one of the channels on each oscilloscope and is only available on 90000 x-, 90000 q-, v-series, and z-series oscilloscopes. on the infiniium 90000 x- and v-series, a maximum of two oscilloscopes can be connected to perform precision calibration. a sync port is available for precision calibration on 90000 q- and z-series.
06 | keysight | n8834a multiscope application - data sheet 2. connect all the scopes to the control pc using lan or usb cables or use the leader scope as the controller. add window add waveform 3. perform calibration using one of the calibration methods. 4. customize the display using the infniium offine oscilloscope analysis software on a pc or the infniium analysis software on the leader scope. multiscope application setup 1. set up a multiscope connection with cables and splitters to create a daisy chain confguration.
07 | keysight | n8834a multiscope application - data sheet 90000 q-series / z-series 90000 x-series/ v-series s-series 90000a series 9000 series dsox95004q/ dsoz504a, dsox96204q/ dsoz634a dsox92004q/ dsoz204a, dsox92504q/ dsoz254a, dsox93304q/ dsoz334a dsov084a, dsox91304a/ dsov134a, dsox91604a / dsov164a, dsox92004a/ dsov204a, dsox92504a/ dsov254a, dsox92804a/ dsov284a, dsox93304a/ dsov334a dsos054a, dsos104a, dsos204a, dsos254a, dsos404a, dsos604a, dsos804a dso90254a, dso90404a, dso90504a, dso90804a, dso91204a, dso91304a dso9064a dso9104a, dso9254a, dso9404a max bandwidth 50 to 63 ghz 33 ghz 20 to 33 ghz 20 to 33 ghz 8 to 16 ghz 6 to 8 ghz 0.5 to 4 ghz 2.5 to 13 ghz 600 mhz 1 to 4 ghz max sample rate 160 gsa/s 80 gsa/s 80 gsa/s 80 gsa/s 40 gsa/s 20 gsa/s 10 gsa/s 40 gsa/s 10 gsa/s 5 gsa/s 20 gsa/s 10 gsa/s max channels/ frame 2 4 4 2 4 2 4 4 2 4 2 4 max frames 10 10 10 10 10 10 sync port not available available available not available not available not available not available external reference frequency 100 mhz 10 mhz 10 mhz 10 mhz 10 mhz calibration modes manual yes yes yes yes yes yes basic (inter-scope intrinsic jitter 2 ) yes (10 ps) yes (10 ps) yes (10 ps) yes (5 ps) yes (5 ps) yes (n/a) precision 1 (inter-scope intrinsic jitter 2 ) yes (0.15 ps) yes (0.5 ps) yes (0.5 ps) no no no cable kit to connect to two frames n2105a n2123a n2124a n2124a n2124a 1. precision calibration is available on 90000 q- and z-series for up to 10 scopes and on 90000 x- and v-series for up to 2 scopes. 2. inter-scope intrinsic jitter value is used to calculate multiscope delta-time measurement accuracy. n8834a infniium multiscope confguration table
08 | keysight | n8834a multiscope application - data sheet application license type infniium v/z-series infniium s-series infniium 90000 series infniium 9000 series infniium analysis software (optional) floating transportable n8900a-001 n8900a-001 n8900a-001 n8900a-001 server-based multiscope software C connect 2 scopes fixed user-installed n8834a-afp n8834a-afp n8834a-afp n8834a-afp floating transportable n8834a-atp n8834a-atp n8834a-atp n8834a-atp server-based n5435a-085 multiscope software C connect up to 5 scopes fixed user-installed n8834a-bfp n8834a-bfp n8834a-bfp n8834a-bfp floating transportable n8834a-btp n8834a-btp n8834a-btp n8834a-btp server-based n5435a-086 multiscope software C connect up to 10 scopes fixed user-installed n8834a-cfp n8834a-cfp n8834a-cfp n8834a-cfp floating transportable n8834a-ctp n8834a-ctp n8834a-ctp n8834a-ctp server-based n5435a-090 multiscope software (upgrade to connect from 2 to up to 5 scopes) fixed user-installed N8834A-DFP N8834A-DFP N8834A-DFP N8834A-DFP floating transportable n8834a-dtp n8834a-dtp n8834a-dtp n8834a-dtp server-based multiscope software (upgrade to connect from 5 to up to 10 scopes) fixed user-installed n8834a-efp n8834a-efp n8834a-efp n8834a-efp floating transportable n8834a-etp n8834a-etp n8834a-etp n8834a-etp server-based note: transportable license is required for viewing the multiscope channels on a pc via hosted mode. recommended oscilloscopes the n8834a multiscope software is compatible with infiniium series oscilloscope with operating software revision 5.60 or higher . for oscilloscopes with earlier revisions, free upgrade software is available at: www.keysight.com/find/scope-apps-sw . 2ughulqj,qirupdwlrqiru,qoqllxp2vfloorvfrsh0xowlvfrsh&rqojxudwlrq software options cable kits n2123a infniium 90000 x- and v-series multi-frame cable kit for two frames n2124a infniium 9000, 90000a, and s-series multi-frame cable kit for two frames n2105a infniium 90000 q- and z-series multi-frame base kit for stacking two frames rdering information for infniivision scilloscope ultiscope onfguration application license type infniivision series infniium analysis software (required) floating transportable n8900a-001 server-based multiscope software C connect 2 scopes floating transportable n8834a-atp server-based n5435a-085 multiscope software C connect up to 5 scopes floating transportable n8834a-btp server-based n5435a-086 multiscope software C connect up to 10 scopes floating transportable n8834a-ctp server-based n5435a-090 multiscope software (upgrade to connect from 2 to up to 5 scopes) floating transportable n8834a-dtp server-based multiscope software (upgrade to connect from 5 to up to 10 scopes) floating transportable n8834a-etp server-based
09 | keysight | n8834a multiscope application - data sheet performance characteristics control pc requirement windows 7 64 bit, minimum 4 g ram (recommended 8 g), 1 g free hard drive space infniium software 5.50 and above note: control pc is not required for infniium series scopes if leader scope is used as the controller. a control pc must be used if infniivision scopes exist in the multiscope confguration leader and followers oscilloscope requirement 1 infniium software 5.50 and above 2 channels supported analog channel 1 to 4 note: digital channels on all mso models are not supported trigger modes 3 edge triggers on a specifed slope (rising, falling, or alternating between rising and falling) and voltage level on any channel or auxiliary trigger glitch triggers on glitches narrower than the other pulses in your waveform by specifying a width less than your narrowest pulse and a polarity note: all other trigger modes are not supported 1. front panel control is disabled during multiscope operation. oscilloscope control is handled by the infiniium offline software on pc or the leader scope. 2. software 4.30 or above requires windows 7. n2753a infiniium windows xp to 7 os upgrade kit (oscilloscope already has m890 motherboard). n2754a infiniium windows xp to 7 os and m890 motherboard upgrade kit (oscilloscope without m890 motherboard). verify the m890 motherboard using the procedure found in the windows 7 upgrade kit data sheet with the publication number 5990-8569en. 3. if leader scope is used as the controller, all trigger modes supported on the leader scope will be available in the multiscope configuration.
10 | keysight | n8834a multiscope application - data sheet www.axiestandard.org advancedtca ? extensions for instrumentation and test (axie) is an open standard that extends the advancedtca for general purpose and semiconductor test. keysight is a founding member of the axie consortium. atca ? , advancedtca ? , and the atca logo are registered us trademarks of the pci industrial computer manufacturers group. www.lxistandard.org lan extensions for instruments puts the power of ethernet and the web inside your test systems. keysight is a founding member of the lxi consortium. www.pxisa.org pci extensions for instrumentation (pxi) modular instrumentation delivers a rugged, pc-based high-performance measurement and automation system.
11 | keysight | n8834a multiscope application - data sheet this information is subject to change without notice. ? keysight technologies, 2015 - 2016 published in usa, may 5, 2016 5992-0511en www.keysight.com mykeysight www.keysight.com/find/mykeysight a personalized view into the information most relevant to you. three-year warranty www.keysight.com/find/threeyearwarranty keysights committed to superior product quality and lower total cost of ownership. keysight is the only test and measurement company with three-year warranty standard on all instruments, worldwide. and, we provide a one-year warranty on many accessories, calibration devices, systems and custom products. keysight assurance plans www.keysight.com/find/assuranceplans up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. keysight infoline www.keysight.com/find/service keysights insight to best in class information management. free access to your keysight equipment company reports and e-library. keysight channel partners www.keysight.com/find/channelpartners get the best of both worlds: keysights measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/n8834a from hewlett-packard through agilent to keysight for more than 75 years, weve been helping you unlock measurement insights. our unique combination of hardware, software and people can help you reach your next breakthrough. unlocking measurement insights since 1939. 1939 the future for more information on keysight technologies products, applications or services, please contact your local keysight office. the complete list is available at: www.keysight.com/find/contactus americas canada (877) 894 4414 brazil 55 11 3351 7010 mexico 001 800 254 2440 united states (800) 829 4444 asia pacifc australia 1 800 629 485 china 800 810 0189 hong kong 800 938 693 india 1 800 11 2626 japan 0120 (421) 345 korea 080 769 0800 malaysia 1 800 888 848 singapore 1 800 375 8100 taiwan 0800 047 866 other ap countries (65) 6375 8100 europe & middle east austria 0800 001122 belgium 0800 58580 finland 0800 523252 france 0805 980333 germany 0800 6270999 ireland 1800 832700 israel 1 809 343051 italy 800 599100 luxembourg +32 800 58580 netherlands 0800 0233200 russia 8800 5009286 spain 800 000154 sweden 0200 882255 switzerland 0800 805353 opt. 1 (de) opt. 2 (fr) opt. 3 (it) united kingdom 0800 0260637 for other unlisted countries: www.keysight.com/find/contactus (bp- 02-10-16) dekra certified iso9001 quality management system www.keysight.com/go/quality keysight technologies, inc. dekra certified iso 9001:2015 quality management system


▲Up To Search▲   

 
Price & Availability of N8834A-DFP

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X